Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 137
Filtrar
1.
Asia Pac J Ophthalmol (Phila) ; 13(1): 100030, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38233300

RESUMEN

PURPOSE: There are major gaps in our knowledge of hereditary ocular conditions in the Asia-Pacific population, which comprises approximately 60% of the world's population. Therefore, a concerted regional effort is urgently needed to close this critical knowledge gap and apply precision medicine technology to improve the quality of lives of these patients in the Asia-Pacific region. DESIGN: Multi-national, multi-center collaborative network. METHODS: The Research Standing Committee of the Asia-Pacific Academy of Ophthalmology and the Asia-Pacific Society of Eye Genetics fostered this research collaboration, which brings together renowned institutions and experts for inherited eye diseases in the Asia-Pacific region. The immediate priority of the network will be inherited retinal diseases (IRDs), where there is a lack of detailed characterization of these conditions and in the number of established registries. RESULTS: The network comprises 55 members from 35 centers, spanning 12 countries and regions, including Australia, China, India, Indonesia, Japan, South Korea, Malaysia, Nepal, Philippines, Singapore, Taiwan, and Thailand. The steering committee comprises ophthalmologists with experience in consortia for eye diseases in the Asia-Pacific region, leading ophthalmologists and vision scientists in the field of IRDs internationally, and ophthalmic geneticists. CONCLUSIONS: The Asia Pacific Inherited Eye Disease (APIED) network aims to (1) improve genotyping capabilities and expertise to increase early and accurate genetic diagnosis of IRDs, (2) harmonise deep phenotyping practices and utilization of ontological terms, and (3) establish high-quality, multi-user, federated disease registries that will facilitate patient care, genetic counseling, and research of IRDs regionally and internationally.


Asunto(s)
Países en Desarrollo , Humanos , Filipinas , China , Tailandia , Malasia
2.
BMJ Open Ophthalmol ; 8(1)2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37278414

RESUMEN

AIMS: To examine the association between obstructive sleep apnoea (OSA) and age-related macular degeneration (AMD), and the subphenotype of AMD with reticular pseudodrusen (RPD). METHODS: Case-control study with 351 participants (211 AMD and 140 controls) using the Epworth Sleepiness Scale (ESS) and the STOP-BANG Questionnaire (SBQ) validated sleep questionnaires. Participant risk of having moderate-to-severe OSA was determined using a binary risk scale based on the ESS and SBQ combined and an ordinal risk scale based on the SBQ. A prior diagnosis of OSA and whether receiving assisted breathing treatment was also ascertained. Retinal imaging allowed AMD and RPD determination. RESULTS: Higher risk of moderate-to-severe OSA according to the binary and ordinal scales was not associated with the presence of AMD (p≥0.519) nor AMD with RPD (p≥0.551). Per point increase in ESS or SBQ questionnaire score was also not associated with AMD nor AMD with RPD (p≥0.252). However, being on assisted breathing treatment for diagnosed OSA was significantly associated with a higher likelihood of having AMD with RPD, but not all AMD, (OR 3.70; p=0.042 and OR 2.70; p=0.149, respectively), when compared with those without diagnosed OSA on treatment. CONCLUSIONS: Formally diagnosed OSA undergoing treatment, increased the likelihood of having AMD with RPD, but not overall AMD compared with those who were not undergoing treatment. Risk-based OSA questionnaires showed no difference in risk for all AMD or AMD with RPD. Future research, using formal sleep studies could further explore the potential role of nocturnal hypoxia in AMD.


Asunto(s)
Degeneración Macular , Drusas Retinianas , Apnea Obstructiva del Sueño , Humanos , Estudios de Casos y Controles , Apnea Obstructiva del Sueño/complicaciones , Degeneración Macular/complicaciones , Drusas Retinianas/complicaciones , Retina
3.
Transl Vis Sci Technol ; 12(3): 20, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36943168

RESUMEN

Purpose: Accurate mapping of phosphene locations from visual prostheses is vital to encode spatial information. This process may involve the subject pointing to evoked phosphene locations with their finger. Here, we demonstrate phosphene mapping for a retinal implant using eye movements and compare it with retinotopic electrode positions and previous results using conventional finger-based mapping. Methods: Three suprachoroidal retinal implant recipients (NCT03406416) indicated the spatial position of phosphenes. Electrodes were stimulated individually, and the subjects moved their finger (finger based) or their eyes (gaze based) to the perceived phosphene location. The distortion of the measured phosphene locations from the expected locations (retinotopic electrode locations) was characterized with Procrustes analysis. Results: The finger-based phosphene locations were compressed spatially relative to the expected locations all three subjects, but preserved the general retinotopic arrangement (scale factors ranged from 0.37 to 0.83). In two subjects, the gaze-based phosphene locations were similar to the expected locations (scale factors of 0.72 and 0.99). For the third subject, there was no apparent relationship between gaze-based phosphene locations and electrode locations (scale factor of 0.07). Conclusions: Gaze-based phosphene mapping was achievable in two of three tested retinal prosthesis subjects and their derived phosphene maps correlated well with the retinotopic electrode layout. A third subject could not produce a coherent gaze-based phosphene map, but this may have revealed that their phosphenes were indistinct spatially. Translational Relevance: Gaze-based phosphene mapping is a viable alternative to conventional finger-based mapping, but may not be suitable for all subjects.


Asunto(s)
Movimientos Oculares , Prótesis Visuales , Humanos , Fosfenos , Trastornos de la Visión , Retina/cirugía
4.
Aging (Albany NY) ; 15(6): 1713-1733, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36795578

RESUMEN

Genetic and epidemiologic studies have significantly advanced our understanding of the genetic factors contributing to age-related macular degeneration (AMD). In particular, recent expression quantitative trait loci (eQTL) studies have highlighted POLDIP2 as a significant gene that confers risk of developing AMD. However, the role of POLDIP2 in retinal cells such as retinal pigment epithelium (RPE) and how it contributes to AMD pathology are unknown. Here we report the generation of a stable human RPE cell line ARPE-19 with POLDIP2 knockout using CRISPR/Cas, providing an in vitro model to investigate the functions of POLDIP2. We conducted functional studies on the POLDIP2 knockout cell line and showed that it retained normal levels of cell proliferation, cell viability, phagocytosis and autophagy. Also, we performed RNA sequencing to profile the transcriptome of POLDIP2 knockout cells. Our results highlighted significant changes in genes involved in immune response, complement activation, oxidative damage and vascular development. We showed that loss of POLDIP2 caused a reduction in mitochondrial superoxide levels, which is consistent with the upregulation of the mitochondrial superoxide dismutase SOD2. In conclusion, this study demonstrates a novel link between POLDIP2 and SOD2 in ARPE-19, which supports a potential role of POLDIP2 in regulating oxidative stress in AMD pathology.


Asunto(s)
Degeneración Macular , Superóxidos , Humanos , Superóxidos/metabolismo , Degeneración Macular/genética , Degeneración Macular/patología , Estrés Oxidativo/genética , Epitelio Pigmentado de la Retina/patología , Células Epiteliales/metabolismo , Pigmentos Retinianos/metabolismo , Proteínas Nucleares/metabolismo
5.
Transl Vis Sci Technol ; 11(9): 4, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-36066322

RESUMEN

Purpose: The electrode to retina (ER) distance is an important contributory factor to the safety and efficacy of a suprachoroidal retinal prosthesis. Measuring ER distance may be performed by different observers during multisite studies. The aim of this study was to assess the interobserver agreement in measuring ER distance. Methods: Three independent, trained observers measured ER distance from the center of each suprachoroidal electrode to the inner retinal pigment epithelium in spectral-domain optical coherence tomography (SD-OCT) B-scans. A total of 121 ER distance measurements from 77 B-scans collected over 5 months from one subject implanted with a second-generation 44-channel suprachoroidal retinal prosthesis (NCT03406416) were made by each observer. Results: ER distance ranged from 208 to 509 µm. Pearson's correlation coefficient (ρ) showed agreement of 0.99 (95% confidence interval [CI] = 0.98-0.99) in measuring ER for each pairwise comparison. The mean difference in ER distance between observers ranged from 2.4 to 6.4 µm with pairwise limits of agreement (95% CI) of ±20 µm (5.5% of mean). Intraclass correlation coefficient (ICC) showed agreement of 0.98 (95% CI = 0.97-0.99) between observers. Conclusions: There is high agreement in measuring ER distances for suprachoroidal retinal prostheses using our systematic approach between multiple, trained observers, supporting the use of a single observer for each image. Translational Relevance: High interobserver agreement outcomes indicate that multiple, trained observers can be used to take ER measurements across different images in suprachoroidal retinal prosthesis studies. This improves multisite study efficiency and gives confidence in interpreting results relating to the safety and efficacy of suprachoroidal retinal prostheses.


Asunto(s)
Prótesis Visuales , Electrodos , Humanos , Variaciones Dependientes del Observador , Retina/diagnóstico por imagen , Retina/cirugía , Tomografía de Coherencia Óptica/métodos
6.
Ophthalmol Retina ; 6(12): 1165-1172, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35709960

RESUMEN

PURPOSE: Relative ellipsoid zone reflectivity (rEZR) has been reported to be reduced in intermediate age-related macular degeneration (iAMD). However, longitudinal changes in rEZR remain unknown. This study investigated the natural history of rEZR in iAMD and its association with risk factors for disease progression, including the presence or extent of drusen volume, reticular pseudodrusen (RPD), and pigmentary abnormalities (PAs). DESIGN: Longitudinal observational study. PARTICIPANTS: Subjects with bilateral large drusen. METHODS: Spectral-domain (SD) OCT images of both eyes from each participant were obtained every 6 months for 3 years. Using an automated rEZR determination approach, the average rEZR of the central 20° macula was determined for each SD-OCT volume scan. Linear mixed models were used to determine the rate of change in rEZR with age (using the cross-sectional data at baseline) and over time (longitudinal data) and the interactions between the rate of rEZR changes with AMD risk factors at baseline. MAIN OUTCOME MEASURES: Relative ellipsoid zone reflectivity and its rate of change with age and over time. RESULTS: A total of 280 eyes from 140 individuals with bilateral large drusen were included in this study. Cross-sectional data showed that rEZR reduced with increasing age (-8.4 arbitrary units [AUs] per decade; 95% confidence interval [CI], -11.5 to -5.2; P < 0.001). Longitudinal data showed that, on average, rEZR declined at a rate of -2.1 AU per year (95% CI, -2.6 to -1.6 AU per year; P < 0.001). Larger RPD area (P = 0.042) at baseline was associated with a faster rate of rEZR decline over time, whereas the presence of PAs and the drusen volume at baseline showed no significant association with rEZR decline over time (P = 0.068 and P = 0.529, respectively). CONCLUSIONS: The rEZR significantly reduces over 3 years in subjects with iAMD, and both the presence and increasing extent of coexistent RPD at baseline are associated with a faster rate of decline. These findings warrant further studies to understand the value of rEZR as a biomarker of AMD progression.


Asunto(s)
Degeneración Macular , Drusas Retinianas , Humanos , Angiografía con Fluoresceína/métodos , Estudios Transversales , Tomografía de Coherencia Óptica/métodos , Drusas Retinianas/etiología , Degeneración Macular/diagnóstico , Degeneración Macular/complicaciones
7.
Transl Vis Sci Technol ; 11(6): 12, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35696133

RESUMEN

Purpose: To report the long-term observations of the electrode-tissue interface and perceptual stability in humans after chronic stimulation with a 44-channel suprachoroidal retinal implant. Methods: Four subjects (S1-4) with end-stage retinitis pigmentosa received the implant unilaterally (NCT03406416). Electrode impedances, electrode-retina distance (measured using optical coherence tomography imaging), and perceptual thresholds were monitored up to 181 weeks after implantation as the subjects used the prosthesis in the laboratory and in daily life. Stimulation charge density was limited to 32 µC/cm2 per phase. Results: Electrode impedances were stable longitudinally. The electrode-retina distances increased after surgery and then stabilized, and were well-described by an asymptotic exponential model. The stabilization of electrode-retina distances was variable between subjects, stabilizing after 45 weeks for S1, 63 weeks for S2, and 24 weeks for S3 (linear regression; Pgradient > 0.05). For S4, a statistically significant increase in electrode-retina distance persisted (P < 0.05), but by the study end point the rate of increase was clinically insignificant (exponential model: 0.33 µm/wk). Perceptual electrical thresholds were stable in one subject, decreased over time in two subjects (linear model; P < 0.05), and increased slightly in one subject but remained within the predefined charge limits (P = 0.02). Conclusions: Chronic stimulation with the suprachoroidal retinal prosthesis over 3 years resulted in stable impedances, small individual changes in perceptual electrical thresholds, and no clinically significant increase in electrode-retina distances after a period of settling after surgery. Translational Relevance: Chronic stimulation with the 44-channel suprachoroidal retinal implant with a charge density of up to 32 µC/cm2 per phase is suitable for long-term use in humans.


Asunto(s)
Retinitis Pigmentosa , Prótesis Visuales , Estimulación Eléctrica/métodos , Humanos , Microelectrodos , Retina/diagnóstico por imagen , Retina/cirugía , Retinitis Pigmentosa/cirugía
8.
Indian J Ophthalmol ; 70(3): 921-929, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35225544

RESUMEN

PURPOSE: This study aimed to investigate the efficacy of human-derived umbilical cord mesenchymal stem cells (HDUMSC) and human-derived umbilical cord mesenchymal stem cells expressing erythropoietin (HDUMSC-EPO) to rescue total degenerated retina in a rat model. METHODS: The study included four treatment groups, namely negative control using normal saline (HBSS) injection, positive control using sodium iodide 60 mg/kg (SI), SI treated with HDUMSC, and SI treated with HDUMSC-EPO given via subretinal and intravenous routes, to test the efficacy of retinal regeneration following SI-induced retinal degeneration. Retinal function in both phases was tested via electroretinography (ERG) and histological staining examining the outer nuclear layer (ONL). RESULTS: There was a statistically significant result (P < 0.05) in the SI treated with HDUMSC-EPO only when comparing day 11 (mean = 23.6 µv), day 18 (mean = 25.2 µv), day 26 (mean = 26.3 µv), and day 32 (mean = 28.2 µv) to the b-wave ERG on day 4 rescue injection day (mean = 12.5 µv). The SI treated with HDUMSC-EPO showed significant improvement in b-wave ERG readings in the Sprague-Dawley (SD) rat but did not restore baseline readings prior to degeneration (day 0). Both treated groups' ONL thicknesses did not show significant changes compared to the negative control group (HBSS) following rescue therapy. CONCLUSION: Total retinal degeneration following intravenous SI injection was observed at 60 mg/kg. SI treated with HDUMSC and HDUMSC-EPO showed no regenerative potential compared to baseline in SI-induced total retina degeneration on ERG or histology, whereas SI treated with HDUMSC-EPO group showed a substantial increase in b-wave ERG amplitude over time.


Asunto(s)
Eritropoyetina , Degeneración Retiniana , Animales , Modelos Animales de Enfermedad , Electrorretinografía , Humanos , Mesodermo/patología , Ratas , Ratas Sprague-Dawley , Retina/patología , Degeneración Retiniana/diagnóstico , Degeneración Retiniana/terapia , Células Madre/patología
9.
Clin Exp Ophthalmol ; 50(1): 31-39, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34652058

RESUMEN

BACKGROUND: Subthreshold nanosecond laser (SNL) treatment has been studied as a potential intervention in intermediate age-related macular degeneration (iAMD). This study investigated the effect of 100 SNL treatment spots on retinal structure and function. METHODS: A prospective single-arm interventional pilot study. SNL treatment was delivered as 100 spots around the retinal vascular arcades of the study eye (worst visual acuity) in a single session in subjects with iAMD. Multimodal retinal imaging and dark-adapted chromatic perimetry were performed at baseline and at 0.5, 3, 6 and 12 months post treatment. Post treatment changes in best corrected visual acuity (BCVA), retinal thickness, relative ellipsoid zone reflectivity (rEZR) and rod-mediated functional parameters were compared to baseline. RESULTS: Twenty-one subjects with iAMD were recruited. SNL treatment was associated with an increase in retinal thickness (p = 0.008) and decrease in rEZR (p < 0.001) at 2 weeks post laser. Recovery of retinal thickness and rEZR was observed at the 3-month post laser visit. A gradual improvement in BCVA was observed after laser treatment. The mean change in BCVA between baseline and 12-month visit was +1.9 ± 3.3 letters for the SNL treated eyes, compared to -0.4 ± 3.0 letters for the fellow eyes (p = 0.027). Rod-mediated function improved at 3 months post laser (p < 0.001) and returned to the baseline levels at 12 months post treatment. CONCLUSIONS: A single treatment with 100 SNL spots causes a short-term change in retinal structure and improvement in retinal function that are apparent at 3 months post treatment.


Asunto(s)
Degeneración Macular , Angiografía con Fluoresceína , Humanos , Rayos Láser , Degeneración Macular/complicaciones , Degeneración Macular/diagnóstico , Degeneración Macular/cirugía , Proyectos Piloto , Estudios Prospectivos , Tomografía de Coherencia Óptica
10.
Indian J Ophthalmol ; 70(1): 201-209, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34937239

RESUMEN

PURPOSE: There are no effective treatments currently available for optic nerve transection injuries. Stem cell therapy represents a feasible future treatment option. This study investigated the therapeutic potential of human umbilical cord-derived mesenchymal stem cell (hUC-MSC) transplantation in rats with optic nerve injury. METHODS: Sprague-Dawley (SD) rats were divided into three groups: a no-treatment control group (n = 6), balanced salt solution (BSS) treatment group (n = 6), and hUC-MSCs treatment group (n = 6). Visual functions were assessed by flash visual evoked potential (fVEP) at baseline, Week 3, and Week 6 after optic nerve crush injury. Right eyes were enucleated after 6 weeks for histology. RESULTS: The fVEP showed shortened latency delay and increased amplitude in the hUC-MSCs treated group compared with control and BSS groups. Higher cellular density was detected in the hUC-MSC treated group compared with the BSS and control groups. Co-localized expression of STEM 121 and anti-S100B antibody was observed in areas of higher nuclear density, both in the central and peripheral regions. CONCLUSION: Peribulbar transplantation of hUC-MSCs demonstrated cellular integration that can potentially preserve the optic nerve function with a significant shorter latency delay in fVEP and higher nuclear density on histology, and immunohistochemical studies observed cell migration particularly to the peripheral regions of the optic nerve.


Asunto(s)
Células Madre Mesenquimatosas , Traumatismos del Nervio Óptico , Animales , Potenciales Evocados Visuales , Humanos , Traumatismos del Nervio Óptico/terapia , Ratas , Ratas Sprague-Dawley , Cordón Umbilical
11.
Transl Vis Sci Technol ; 10(12): 14, 2021 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-34636906

RESUMEN

Purpose: Identifying the most sensitive functional measure in intermediate age-related macular degeneration (iAMD) could help select an appropriate test for monitoring disease progression and evaluating the efficacy of novel interventions for the early stages of AMD. The purpose of the study was to determine which commonly used visual function test is the most discriminatory when comparing individuals with iAMD to normal participants. Methods: In this prospective observational study, iAMD cases and healthy controls underwent visual function testing (best corrected visual acuity (BCVA), low luminance visual acuity (LLVA), mesopic microperimetry, dark adaptation, and scotopic perimetry following photobleach), clinical eye examination, and multimodal retinal imaging in a single study visit. The data of each functional parameter were converted into z-score so that all the parameters had a common scale to allow a direct comparison between different functional parameters. Results: Forty-eight subjects (23 normal control, 25 iAMD) participated. Although all five parameters showed a significant reduction in function in iAMD eyes compared to controls (P ≤ 0.003), the rod intercept time (RIT) detected the greatest reduction in function followed by the scotopic sensitivity, mesopic sensitivity, BCVA, and LLVA, with the absolute mean z-score of 4.5, 2.2, 1.0, 1.0, and 1.2, respectively. Conclusions: Among the five visual function parameters commonly used, RIT is the most discriminatory functional parameter in the early stages of AMD. Translational Relevance: The RIT could be considered for assessing visual function and evaluating efficacy of novel interventions aimed at improving retinal function in eyes with early stages of AMD.


Asunto(s)
Degeneración Macular , Estudios Transversales , Humanos , Degeneración Macular/diagnóstico , Retina/diagnóstico por imagen , Agudeza Visual , Pruebas del Campo Visual
12.
Invest Ophthalmol Vis Sci ; 62(13): 8, 2021 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-34643661

RESUMEN

Purpose: Cell-based therapy development for geographic atrophy (GA) in age-related macular degeneration (AMD) is hampered by the paucity of models of localized photoreceptor and retinal pigment epithelium (RPE) degeneration. We aimed to characterize the structural and functional deficits in a laser-induced nonhuman primate model, including an analysis of the choroid. Methods: Macular laser photocoagulation was applied in four macaques. Fundus photography, optical coherence tomography (OCT), dye angiography, and OCT-angiography were conducted over 4.5 months, with histological correlation. Longitudinal changes in spatially resolved macular dysfunction were measured using multifocal electroretinography (MFERG). Results: Lesion features, depending on laser settings, included photoreceptor layer degeneration, inner retinal sparing, skip lesions, RPE elevation, and neovascularization. The intralesional choroid was degenerated. The normalized mean MFERG amplitude within lesions was consistently lower than control regions (0.94 ± 0.35 vs. 1.10 ± 0.27, P = 0.032 at month 1, 0.67 ± 0.22 vs. 0.83 ± 0.15, P = 0.0002 at month 2, and 0.97 ± 0.31 vs. 1.20 ± 0.21, P < 0.0001 at month 3.5). The intertest variation of mean MFERG amplitudes in rings 1 to 5 ranged from 13.0% to 26.0% in normal eyes. Conclusions: Laser application in this model caused localized outer retinal, RPE, and choriocapillaris loss. Localized dysfunction was apparent by MFERG in the first month after lesion induction. Correlative structure-function testing may be useful for research on the functional effects of stem cell-based therapy for GA. MFERG amplitude data should be interpreted in the context of relatively high intertest variability of the rings that correspond to the central macula. Sustained choroidal insufficiency may limit long-term subretinal graft viability in this model.


Asunto(s)
Electrorretinografía/métodos , Angiografía con Fluoresceína/métodos , Atrofia Geográfica/patología , Segmento Externo de las Células Fotorreceptoras Retinianas/patología , Tomografía de Coherencia Óptica/métodos , Animales , Modelos Animales de Enfermedad , Fondo de Ojo , Atrofia Geográfica/fisiopatología , Macaca fascicularis , Epitelio Pigmentado de la Retina/patología , Epitelio Pigmentado de la Retina/fisiopatología , Agudeza Visual
13.
Transl Vis Sci Technol ; 10(10): 12, 2021 08 12.
Artículo en Inglés | MEDLINE | ID: mdl-34581770

RESUMEN

Purpose: To report the initial safety and efficacy results of a second-generation (44-channel) suprachoroidal retinal prosthesis at 56 weeks after device activation. Methods: Four subjects, with advanced retinitis pigmentosa and bare-light perception only, enrolled in a phase II trial (NCT03406416). A 44-channel electrode array was implanted in a suprachoroidal pocket. Device stability, efficacy, and adverse events were investigated at 12-week intervals. Results: All four subjects were implanted successfully and there were no device-related serious adverse events. Color fundus photography indicated a mild postoperative subretinal hemorrhage in two recipients, which cleared spontaneously within 2 weeks. Optical coherence tomography confirmed device stability and position under the macula. Screen-based localization accuracy was significantly better for all subjects with device on versus device off. Two subjects were significantly better with the device on in a motion discrimination task at 7, 15, and 30°/s and in a spatial discrimination task at 0.033 cycles per degree. All subjects were more accurate with the device on than device off at walking toward a target on a modified door task, localizing and touching tabletop objects, and detecting obstacles in an obstacle avoidance task. A positive effect of the implant on subjects' daily lives was confirmed by an orientation and mobility assessor and subject self-report. Conclusions: These interim study data demonstrate that the suprachoroidal prosthesis is safe and provides significant improvements in functional vision, activities of daily living, and observer-rated quality of life. Translational Relevance: A suprachoroidal prosthesis can provide clinically useful artificial vision while maintaining a safe surgical profile.


Asunto(s)
Retinitis Pigmentosa , Prótesis Visuales , Actividades Cotidianas , Humanos , Calidad de Vida , Visión Ocular
14.
Transl Vis Sci Technol ; 10(7): 9, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-34110385

RESUMEN

Purpose: Artificial intelligence (AI) techniques are increasingly being used to classify retinal diseases. In this study we investigated the ability of a convolutional neural network (CNN) in categorizing histological images into different classes of retinal degeneration. Methods: Images were obtained from a chemically induced feline model of monocular retinal dystrophy and split into training and testing sets. The training set was graded for the level of retinal degeneration and used to train various CNN architectures. The testing set was evaluated through the best architecture and graded by six observers. Comparisons between model and observer classifications, and interobserver variability were measured. Finally, the effects of using less training images or images containing half the presentable context were investigated. Results: The best model gave weighted-F1 scores in the range 85% to 90%. Cohen kappa scores reached up to 0.86, indicating high agreement between the model and observers. Interobserver variability was consistent with the model-observer variability in the model's ability to match predictions with the observers. Image context restriction resulted in model performance reduction by up to 6% and at least one training set size resulted in a model performance reduction of 10% compared to the original size. Conclusions: Detecting the presence and severity of up to three classes of retinal degeneration in histological data can be reliably achieved with a deep learning classifier. Translational Relevance: This work lays the foundations for future AI models which could aid in the evaluation of more intricate changes occurring in retinal degeneration, particularly in other types of clinically derived image data.


Asunto(s)
Aprendizaje Profundo , Degeneración Retiniana , Animales , Inteligencia Artificial , Gatos , Redes Neurales de la Computación , Degeneración Retiniana/diagnóstico
15.
Ophthalmol Retina ; 5(12): 1196-1203, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-33662615

RESUMEN

PURPOSE: To evaluate the long-term effect of subthreshold nanosecond laser (SNL) treatment on progression to late age-related macular degeneration (AMD). DESIGN: Observational extension study of a randomized, sham-controlled trial. PARTICIPANTS: Two hundred twelve participants with bilateral large drusen. METHODS: The Laser Intervention in the Early Stages of AMD (LEAD) study was a 36-month trial where participants were randomized to receive SNL or sham treatment in 1 eye at 6-monthly intervals up to 30 months. After the completion of the LEAD study, the 2 largest recruiting sites offered remaining participants an opportunity to enroll in a 24-month observational extension study. This study thus examined all participants from these 2 sites who were enrolled in the LEAD study at baseline, including the additional observational data. MAIN OUTCOME MEASURES: Time to develop late AMD, defined on multimodal imaging, between those randomized the SNL or sham treatment. RESULTS: Overall, no significant difference was found in the rate of progression over a 60-month period in those randomized to the SNL compared with the sham group (adjusted hazard ratio [HR], 0.63; 95% confidence interval [CI], 0.36-1.09; P = 0.098), similar to the findings at 36 months in the LEAD Study. However, evidence of treatment effect modification continued to emerge based on the coexistence of reticular pseudodrusen (RPD; P = 0.007, adjusted interaction). Namely, progression was slowed significantly with SNL treatment for those without coexistent RPD (adjusted HR, 0.34; 95% CI, 0.16-0.71; P = 0.004), but it was not significantly different for those with RPD (adjusted HR, 1.81; 95% CI, 0.67-4.88; P = 0.239). CONCLUSIONS: A 24-month observational extension study to the LEAD Study confirmed that SNL treatment did not significantly reduce the overall rate of progression to late AMD in a cohort with intermediate AMD. However, the persistence of a potential beneficial treatment effect in those without coexistent RPD over a longer follow-up duration of an additional 24 months without additional treatment is encouraging. These findings provide further justification for future trials to examine the potential value of SNL treatment for slowing progression in intermediate AMD.


Asunto(s)
Angiografía con Fluoresceína/métodos , Terapia por Láser/métodos , Degeneración Macular/cirugía , Imagen Multimodal/métodos , Drusas Retinianas/cirugía , Anciano , Progresión de la Enfermedad , Femenino , Fondo de Ojo , Humanos , Degeneración Macular/complicaciones , Degeneración Macular/diagnóstico , Masculino , Drusas Retinianas/diagnóstico , Drusas Retinianas/etiología , Factores de Riesgo , Resultado del Tratamiento
16.
Tissue Eng Regen Med ; 18(1): 143-154, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33415670

RESUMEN

BACKGROUND: Different methods have been used to inject stem cells into the eye for research. We previously explored the intravitreal route. Here, we investigate the efficacy of intravenous and subretinal-transplanted human dental pulp stem cells (DPSCs) in rescuing the photoreceptors of a sodium iodate-induced retinal degeneration model. METHODS: Three groups of Sprague Dawley rats were used: intervention, vehicle group and negative control groups (n = 6 in each). Intravenous injection of 60 mg/kg sodium iodate (day 0) induced retinal degeneration. On day 4 post-injection of sodium iodate, the rats in the intervention group received intravenous DPSC and subretinal DPSC in the right eye; rats in the vehicle group received subretinal Hank's balance salt solution and intravenous normal saline; while negative control group received nothing. Electroretinogram (ERG) was performed to assess the retinal function at day 0 (baseline), day 4, day 11, day 18, day 26, and day 32. By the end of the study at day 32, the rats were euthanized, and both their enucleated eyes were sent for histology. RESULTS: No significant difference in maximal ERG a-wave (p = 0.107) and b-wave, (p = 0.153) amplitude was seen amongst the experimental groups. However, photopic 30 Hz flicker amplitude of the study eye showed significant differences in the 3 groups (p = 0.032). Within the intervention group, there was an improvement in 30 Hz flicker ERG response of all 6 treated right eyes, which was injected with subretinal DPSC; while the 30 Hz flicker ERG of the non-treated left eyes remained flat. Histology showed improved outer nuclear layer thickness in intervention group; however, findings were not significant compared to the negative and vehicle groups. CONCLUSION: Combination of subretinal and intravenous injection of DPSCs may have potential to rescue cone function from a NaIO3-induced retinal injury model.


Asunto(s)
Degeneración Retiniana , Animales , Pulpa Dental , Modelos Animales de Enfermedad , Humanos , Yodatos , Ratas , Ratas Sprague-Dawley , Degeneración Retiniana/inducido químicamente , Degeneración Retiniana/terapia , Células Madre
17.
Doc Ophthalmol ; 142(2): 197-211, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32968834

RESUMEN

PURPOSE: An orientation-specific visual evoked potential (osVEP) protocol was developed to probe meridional anisotropies in children with refractive amblyopia. The aim was to characterise the osVEP response in children with bilateral refractive amblyopia, evaluate the intra-session repeatability of the main osVEP components (C1, C2 and C3), coefficient of repeatability (CoR) of the response to gratings in different meridians and determine if refractive amblyopes have poorer repeatability as compared with non-amblyopic controls. METHODS: Children aged 4-7 years with newly diagnosed and untreated bilateral refractive amblyopia and non-amblyopic controls were recruited. Orientation-specific pattern-onset VEPs were recorded in response to an achromatic sinewave grating stimulus of 4 cycles per degree under monocular and binocular stimulation. The grating lines used for monocular stimulation were parallel with the subjects' most positive and negative astigmatic meridians when considered in sphero-minus cylinder form (Meridians 1 and 2, respectively). In subjects without astigmatism, meridians 1 and 2 were designated horizontal and vertical gratings, respectively. Binocular stimuli were presented with grating lines parallel to meridians 45, 90, 135 and 180°. The repeatability of latencies of the main osVEP components (C1, C2 and C3) were investigated using two successive osVEPs recordings for each stimulus meridian and the CoR for each component's latencies were assessed. RESULTS: Seven amblyopic children (Visual acuity (VA) ranging from 0.08 to 0.40 LogMAR in the less amblyopic eye and 0.26-0.52 LogMAR in the more amblyopic eye) and 7 non-amblyopic controls (VA ranging from 0.00 to 0.02 LogMAR in either eye), with a median age of 4.6 and 7.0 years, respectively, completed the study. C1 had the highest CoR for most conditions assessed. Ratio of CoRs C1:C2 was > 2 for all binocular meridians in controls and the 90 and 180 meridians in the amblyopes; C1:C3 was > 2 for the binocularly assessed 45, 90 and 135 meridians in the controls and the 90 and 180 meridians in the amblyopes; C2:C3 were all < 2 for all meridians assessed in both groups. CONCLUSIONS: The osVEP waveforms are reliable and useful for future investigations into the meridional anisotropies in children with refractive amblyopia, particularly the C3 component. Component C1 had the poorest repeatability, which consequentially affected C2 amplitude estimation. Only C3 amplitude and latency could be consistently estimated as C2 and C3 latencies were similarly repeatable. Coefficients of repeatability of osVEP latencies did not appear to systematically differ between non-amblyopic and amblyopic children.


Asunto(s)
Ambliopía , Potenciales Evocados Visuales , Niño , Preescolar , Electrorretinografía , Humanos , Factores de Tiempo , Agudeza Visual
18.
Br J Ophthalmol ; 105(5): 711-715, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-32606079

RESUMEN

PURPOSE: To examine the added predictive value of microperimetric sensitivity and low luminance deficit (LLD; difference between photopic and low luminance visual acuity (VA)) to information from colour fundus photography (CFP) for progression to late age-related macular degeneration (AMD) in individuals with bilateral large drusen. METHODS: 140 participants with bilateral large drusen underwent baseline microperimetry testing, VA measurements and CFP. They were then reviewed at 6-monthly intervals to 36 months, to determine late AMD progression. Microperimetry pointwise sensitivity SD (PSD), LLD and the presence of pigmentary abnormalities on CFPs were determined. Predictive models based on these parameters were developed and examined. RESULTS: Baseline microperimetry PSD and presence of pigmentary abnormalities were both significantly associated with time to develop late AMD (p≤0.004), but LLD was not (p=0.471). The area under the receiver operating characteristic curve (AUC) for discriminating between eyes that progressed to late AMD based on models using microperimetry PSD (AUC=0.68) and LLD (AUC=0.58) alone was significantly lower than that based on CFP grading for the presence of pigmentary abnormalities (AUC=0.80; both p<0.005). Addition of microperimetry and/or LLD information to a model that included CFP grading did not result in any improvement in its predictive performance (AUC=0.80 for all; all p≥0.66). CONCLUSIONS: While microperimetry, but not LLD, was significantly and independently associated with AMD progression at the population level, this study observed that both measures were suboptimal at predicting progression at the individual level when compared to conventional CFP grading and their addition to the latter did not improve predictive performance.


Asunto(s)
Degeneración Macular/diagnóstico , Agudeza Visual , Pruebas del Campo Visual/métodos , Campos Visuales/fisiología , Anciano , Anciano de 80 o más Años , Progresión de la Enfermedad , Femenino , Humanos , Luz , Degeneración Macular/fisiopatología , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Tomografía de Coherencia Óptica
19.
Retina ; 41(5): 1094-1101, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33009222

RESUMEN

PURPOSE: To evaluate the performance of microperimetry and low-luminance visual acuity for detecting late age-related macular degeneration (AMD) onset. METHODS: Two hundred ninety-two individuals with bilateral large drusen in the Laser Intervention in the Early Stages of AMD study underwent best-corrected visual acuity, low-luminance visual acuity, and microperimetry testing as well as multimodal imaging to detect late (neovascular or atrophic) AMD onset. The performance of the change in the measurement from baseline of each of visual function test for detecting late AMD onset was compared. RESULTS: The area under the receiver operating characteristic curve for detecting neovascular and atrophic AMD onset was not significantly different for low-luminance visual acuity (area under the receiver operating characteristic curve = 0.71 and 0.56, respectively) and microperimetry (area under the receiver operating characteristic curve = 0.82 and 0.62, respectively) compared with best-corrected visual acuity (area under the receiver operating characteristic curve = 0.57 and 0.56, respectively; P ≥ 0.126 for all). There was also only a fair degree of agreement between the three visual function measures for detecting the onset of neovascular and atrophic AMD (κ ≥ 0.24). CONCLUSION: Microperimetry, low-luminance visual acuity, and best-corrected visual acuity demonstrate limited performance for detecting the earliest onset of late AMD. It remains to be established whether they perform better than current methods designed to enable self-detection of neovascular AMD onset, such as Amsler grid testing.


Asunto(s)
Luz , Agudeza Visual/fisiología , Pruebas del Campo Visual/métodos , Campos Visuales/fisiología , Degeneración Macular Húmeda/diagnóstico , Anciano , Anciano de 80 o más Años , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Degeneración Macular Húmeda/fisiopatología
20.
Front Cell Neurosci ; 14: 570917, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33132845

RESUMEN

CRISPR/Cas has opened the prospect of direct gene correction therapy for some inherited retinal diseases. Previous work has demonstrated the utility of adeno-associated virus (AAV) mediated delivery to retinal cells in vivo; however, with the expanding repertoire of CRISPR/Cas endonucleases, it is not clear which of these are most efficacious for retinal editing in vivo. We sought to compare CRISPR/Cas endonuclease activity using both single and dual AAV delivery strategies for gene editing in retinal cells. Plasmids of a dual vector system with SpCas9, SaCas9, Cas12a, CjCas9 and a sgRNA targeting YFP, as well as a single vector system with SaCas9/YFP sgRNA were generated and validated in YFP-expressing HEK293A cell by flow cytometry and the T7E1 assay. Paired CRISPR/Cas endonuclease and its best performing sgRNA was then packaged into an AAV2 capsid derivative, AAV7m8, and injected intravitreally into CMV-Cre:Rosa26-YFP mice. SpCas9 and Cas12a achieved better knockout efficiency than SaCas9 and CjCas9. Moreover, no significant difference in YFP gene editing was found between single and dual CRISPR/SaCas9 vector systems. With a marked reduction of YFP-positive retinal cells, AAV7m8 delivered SpCas9 was found to have the highest knockout efficacy among all investigated endonucleases. We demonstrate that the AAV7m8-mediated delivery of CRISPR/SpCas9 construct achieves the most efficient gene modification in neurosensory retinal cells in vivo.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...